A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the EXTECH INSTRUMENTS EX450 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   EXTECH INSTRUMENTS EX450 (450)   Description / Specification:    
EXTECH INSTRUMENTS EX450 True RMS Autoranging Multimeter with IR Thermometer

The Extech EX450 MultiMeter with IR Laser Thermometer is a Combination Autoranging True RMS multimeter with a built-in IR Thermometer. It features low current capability (measure down to 0.1uA), audible and visual input alerts, an easy to read 1 inch digits on backlit display, and a Max Hold for AC/DC Voltage and Current measurements and Relative function for establishing a baseline for reference.
Specifications.

Temperature (IR): -58 to 518˚F (-50 to 270˚C).
Averaging/True RMS: Averaging.
Basic Accuracy: ±0.5%.
AC Voltage: 1mV to 750V.
DC Voltage: 0.1mV to 1000V.
AC Current: 0.1μA to 20A.
DV Current: 0.1μA to 20A.
Resistance: 0.1 Ohm to 20 MOhm.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your EXTECH INSTRUMENTS EX450 CALIBRATION and/or EXTECH INSTRUMENTS EX450 True RMS Autoranging Multimeter with IR Thermometer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: